SMART-UPS SERIES
Protect your equipment and your data with reliable backup power and orderly shutdowns.
Key Features
APC $25,000 lifetime equipment protection. Lightning and surge protection. Automatic shutdown protection if your primary utility input fails. Instant emergency backup power. Network interface facilitates automatic shutdown for file servers. EMI/RMI filtering, SmartBoostTM to correct brownouts, and SmartTrimTM to correct overvoltages.
W
ith the APC line of uninterruptible power supplies (UPSs), your sensitive computer systems will be protected in the event of power blackouts, brownouts, swells, sags, surges, and interference. Each UPS provides enough backup power for you to perform an orderly shutdown should a power failure occur. In addition, each UPS is equipped with highgrade surge suppression and noise filtering to give your equipment a constant supply of clean power--whether from utility or battery power. Under normal conditions, the UPS supplies power from the utility input to the load. But if the utility fails, the converter supplies AC power to the load and the disconnect switch opens. The load continues to operate normally until shutdown or until the battery wears down. Once the
line voltage returns to normal, the UPS automatically transfers the load back to utility power. Visual and audible indications keep track of the battery's capacity and current condition, including when it is low or overloaded, or when it needs to be replaced. The UPS performs a self-test on the battery during power-up and every 14 days-- which gives you enough time to replace it before a problem develops. You can also manually perform a self-test with the on/test button. And batteries can be replaced without removing power from loads or sending the UPS in for service. The Smart-UPS Series has numerous varieties of backup power supplies. Choose the one that offers the most protection to fit your needs from standalone and rackmount models.
All include PowerChute Plus management software. Install the PowerChute software on your PC; then connect to the SmartUPS through the serial port. This lets you access a myriad of powerful management features such as periodic server shutdown and reboot, alarm settings, selftests, calibration, predictive failure analysis, data logs, and more. The SUA1000 and SUA1500 standalone UPSs and all of the rackmount Smart-UPSs feature a convenient USB port which may be used instead of the serial port. Rackmount models fit into any standard 19" rack to provide power protection for switches, routers, and other vital network devices.
(R) (R)
1
7/7/2004
#17226
www..com
Operation: Smart-UPS Standalone Models
Includes PowerChute software Normal Input Voltage Transfer Time SmartBoost and SmartTrim Rated Power/Nom. Input Voltage Load Power Factor Range, Crest Factor Range Surge Energy Rating Normal Mode Surge Voltage Let-Through SU420NET SU620NET SP540A SUA1000 SUA1500 SP543A SP544A SU5000T Supports Linux , Novell , Solaris , Windows 2003, Windows XP, Windows 2000, and Windows NT
(R) (R) (R) (R) (R)
120 VAC, single phase, 50 or 60 Hz (autosensing) 2 ms typical, 4 ms maximum On-line operation for input between 90-145 VAC; Output is 103-132 VAC; SmartBoost increases voltage 12% if input is 90-103 VAC; SmartTrim reduces voltage 12% if input is 145-132 VAC; Transfer points are user-adjustable with software
420 VA/260 W 620 VA/390 W 700 VA/450 W 1000 VA/670 W 1400 VA/950 W 2200 VA/1600 W 3000 VA/2250 W 5000 VA/3750 W
0.5 to 1.0 < 5 320 joules, 6.5 kA <0.7% of peak typical <0.3% of peak typical 480 joules
Operation: Smart-UPS Rackmount Models
SUA750RM2U Includes PowerChute software Nominal Input Voltage Transfer Time SmartBoost and SmartTrim Output Power Capacity Load Power Factor Range, Crest Factor Range Surge Energy Rating Sealed, maintenancefree lead acid batteries with 3-6 year typical life (2) 12 V, 4.5 AH 480 joules (2) 12 V, 7 AH 750 VA/ 480 W SUA1000RM2U SUA1500RM2U SU3000RMNET Supports Linux, Novell, Solaris, Windows 2003, Windows XP, Windows 2000, and Windows NT
120 VAC, 50/60 Hz 3 Hz (autosensing) 2 ms typical, 4 ms maximum On-line operation for input between 90-145 VAC; Output is 103-132 VAC; Smart Boost increases voltage 12% if input is 90-103 VAC; SmartTrim reduces voltage 12% if input is 145-132 VAC; Transfer points are user-adjustable with software 1000 VA/ 670 W 1500 VA/ 1005 W 0 to < 5 nanoseconds 3000 VA/ 2700 W
800 joules (4) 12 V, 9 AH
880 joules (8) 12 V, 7 AH
2
www..com
Determining On-Battery Run Time
without losing valuable information. To determine on-battery run time, find out the load time protected by the UPS in Volt-Amps. Load figures can be found on the protected equipment itself or in the manuals that came with it. Multiply the figure by 1.4 for loads specified in watts; multiply the specified figure by 120 for loads specified in amps. Add the individual loads to determine the total load. Compare your system's total load to the table below.
Knowing the on-battery run time of your UPS is important-- especially if your protected devices use an operating system that needs time to shut down
Typical On-Battery Run Time versus Load, in Minutes
Model Watts 50 VA 70 SU420NET 55 SU620NET 1 hr. 40 min. SP540A 2 hr. 4 min. SUA1000 3 hr. 3 min. SUA1500 5 hr. 1 min. SP543A 8 hr. 51 min. SP544A 8 hr. 51 min. SU5000T 5 hr. 19 min. SUA750RM2U 2 hr. 4 min. SUA1000RM2U 2 hr. 10 min. SUA1500RM2U 5 hr. 21 min. SU3000RMNET 8 hr. 51 min. Model SU420NET SU620NET SP540A SUA1000 SUA1500 SP543A SP544A SU5000T SUA750RM2U SUA1000RM2U SUA1500RM2U SU3000RMNET Watts VA 100 140 21 45 1 hr. 0 min. 1 hr. 40 min. 2 hr. 52 min. 5 hr. 36 min. 5 hr. 36 min. 3 hr. 6 min. 1 hr. 0 min. 1 hr. 11 min. 3 hr. 5 min. 5 hr. 36 min. 1200 1680 -- -- -- -- -- 17 17 12 -- -- -- 17 200 280 6 15 23 45 1 hr. 0 min. 3 hr. 6 min. 3 hr. 6 min. 1 hr. 28 min. 23 31 1 hr. 31 min. 3 hr. 5 min. 1400 1960 -- -- -- -- -- 13 13 10 -- -- -- 13 Time (unless noted, is in minutes) 300 400 500 420 560 700 -- -- -- 7 -- -- 11 25 35 2 hr. 2 min. 2 hr. 2 min. 1 hr. 4 min. 11 16 55 2 hr. 2 min. 1600 2240 -- -- -- -- -- 10 10 8 -- -- -- 10 7 15 23 1 hr. 28 min. 1 hr. 28 min. 47 7 10 37 1 hr. 28 min. 1800 2520 -- -- -- -- -- -- 8 6 -- -- -- 8 -- 10 15 1 hr. 0 min. 1 hr. 6 min. 37 -- 7 26 1 hr. 6 min. 2000 2800 -- -- -- -- -- -- 7 -- -- -- -- 7 600 840 -- -- -- 7 11 52 52 30 -- 6 19 52 700 980 -- -- -- -- -- 42 42 28 -- -- 14 42 800 1120 -- -- -- -- -- 34 34 21 -- -- 11 34 900 1260 -- -- -- -- -- 28 28 18 -- -- 9 28 1000 1400 -- -- -- -- -- 24 24 16 -- -- -- 24
2500 3500 -- -- -- -- -- -- -- -- -- -- -- --
3500 4200 -- -- -- -- -- -- -- -- -- -- -- --
Full Load 9 min. (165 watts) 5 min. (260 watts) 6 min. (450 watts) 6 min. (670 watts) 7 min. (980 watts) 10 min. (1600 watts) 6 min. (2250 watts) 5 min. (1980 watts) 6 min. (480 watts) 5 min. (640 watts) 7 min. (980 watts) 6 min. (2250 watts)
Half Load 30 min. 82.5 watts 14 min. (130 watts) 19 min. (225 watts) 21 min. (335 watts) 24 min. (490 watts) 34 min. (800 watts) 19 min. (1125 watts) 16 min. (800 watts) 17 min. (240 watts) 15 min. (320 watts) 26 min. (490 watts) 19 min. (1125 watts)
3
www..com
Specifications
Interface: SU420NET, SU620NET: (1) RS-232 DB9, (1) RJ-11, (1) RJ-45; SP540A, SP543A-SP544A: (1) RS-232 DB9, (1) SmartSlot; SUA1000, SUA1500, SUA750RM2U, SUA1000RM2U, SUA1500RM2U, SU3000RMNET: (1) RS-232 DB9, (1) SmartSlot, (1) USB; SU5000T: (1) RS-232 DB9, (2) SmartSlots, (1) 10BASE-T Ethernet for Web/SNMP/ Telnet management Connectors (Number of Outlets): SU420NET, SU620NET, SP540A: (4) NEMA 5-15R; SUA750RM2U, SUA1000RM2U, SUA1500RM2U: (6) NEMA 5-15R; SP543A-SP544A, SU3000RMNET, SUA1000, SUA1500: (8) NEMA 5-15R; SU5000T: (1) NEMA L6-30R (30 amp), (2) NEMA L6-20R (20 amp), (2) NEMA 5-15R (15 amp) Indicators: SU420NET, SU620NET: LEDs: On Line, On Battery, Replace Battery, Overload, Site Wiring Fault; Audible Alarms: On Battery, Low Battery; SP540A, SUA1000, SUA1500, SP543A-SP544A, SUA1500RM2U, SU3000RMNET, SU5000T: LEDs: On Battery, Replace Battery, Overload, Site Wiring Fault, Load and Volt Meters, Automatic Diagnostic Testing; Audible Alarms: On Battery, Low Battery, Configurable Delays; SUA750RM2U, SUA1000RM2U: LED status display with Load and Battery bar-graphs; Additional LEDs: On Line, On Battery, Replace Battery, and Overload; Audible Alarms: On Battery, Low Battery, Configurable Delays; Temperature Tolerance: Operating: 32 to 113F (0 to 45C); Storage: 5 to +149F (-15 to +65C) Humidity Tolerance: Up to 95%, noncondensing Size: SU420NET, SU620NET: 6.6"H x 4.7"W x 14.5"D (16.8 x 11.9 x 36.8 cm); SP540A: 6.2"H x 5.4"W x 14.1"D (15.7 x 13.7 x 35.8 cm); SUA1000, SUA1500: 8.5"H x 6.7"W x 17.3"D (21.6 x 17 x 43.9 cm); SP543A-SP544A: 17"H x 7.7"W x 21.5"D (43.2 x 19.6 x 54.6 cm); SUA750RM2U, SUA1000RM2U: SUA1500RM2U: 4"H x 19"W x 18"D (10.1 x 48.3 x 45.7 cm); SU3000RMNET: 8.75"H (5U) x 19"W x 17.8"D (22.2 x 48.3 x 45.2 cm); SU5000T: 17.3"H x 9"W x 26.2"D (43.9 x 22.9 x 66.5 cm) Weight: SU420NET: 22 lb. (10 kg); SU620NET: 27 lb. (12.2 kg); SP540A: 29 lb. (13.2 kg); SUA1000: 41 lb. (18.6 kg); SUA1500: 53 lb. (24 kg); SP543A: 112 lb. (50.8 kg); SP544A: 123 lb. (55.8 kg); SU5000T: 230 lb. (104.3 kg); SUA750RM2U: 48 lb. (21.8 kg); SUA1000RM2U: 62 lb. (28.1 kg); SUA1500RM2U: 63 lb. (28.6 kg); SU3000RMNET: 129 lb. (58.5 kg)
Ordering Information
ITEM APC PART # CODE Standalone Smart-UPS Smart-UPS 420 (SmartSlot not included) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SU420NET Smart-UPS 620 (SmartSlot not included) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SU620NET Smart-UPS 700 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SU700NET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SP540A Smart-UPS 1000 USB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SUA1000 Smart-UPS 1500 USB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SUA1500 Smart-UPS 2200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SU2200NET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SP543A Smart-UPS 3000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SU3000NET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SP544A Smart-UPS 5000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SU5000T To provide additional run time for your SP544A, order... 3000 Battery Pack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BP544 For rackmountable models, choose... Rackmountable Smart-UPS Series 750 VA, 2U. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SUA750RM2U 1000 VA, 2U. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SUA1000RM2U 1500 VA, 2U. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SUA1500RM2U 3000 VA, 5U. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SU3000RMNET To customize your SmartSlot equipped Smart-UPS for easier power management, order... Expansion Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AP9600 Web/SNMP Management Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AP9617 Smart-UPS Interface Expander. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AP9607 Relay I/O Module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AP9610 Measure-UPS Temperature/Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AP9612TH
4


▲Up To Search▲   

 
Price & Availability of SUA1000RM2U

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X